Selecting the right sterilizer for your application is crucial
Performance, ease of use and reliability are essential for sustaining maximum productivity.
With chamber capacities ranging from 160 through to 3000+ litres and available in single-ended and pass-through configurations, BMM Weston steam sterilizers offer a solution to meet your needs.
Combining functionality, high specification and premium UK engineering, BMM Weston steam sterilizers are the number one choice for today’s demanding environment.
Selecting the right sterilizer for your application is crucial
Performance, ease of use and reliability are essential for sustaining maximum productivity.
With chamber capacities ranging from 160 through to 3000+ litres and available in single-ended and pass-through configurations, BMM Weston steam sterilizers offer a solution to meet your needs.
Combining functionality, high specification and premium UK engineering, BMM Weston steam sterilizers are the number one choice for today’s demanding environment.
Selecting the right sterilizer for your application is crucial
Performance, ease of use and reliability are essential for sustaining maximum productivity.
With chamber capacities ranging from 160 through to 3000+ litres and available in single-ended and pass-through configurations, BMM Weston steam sterilizers offer a solution to meet your needs.
Combining functionality, high specification and premium UK engineering, BMM Weston steam sterilizers are the number one choice for today’s demanding environment.
10.4”Full Colour Touch Screen Display
Intuitive User Interface
Our steam sterilizers are fitted with a user-friendly and intuitive interface that allows the appropriate cycle to be selected quickly and easily. When the cycle is in progress, important cycle information is displayed. This includes the current stage along with time, temperature and pressure values. The user is informed of any safety concerns via automatic alerts and alarms. Multi-level user access to special menus is password-protected:
- Supervisor access
- Validation
- Machine configuration
- Maintenance
- Cycle log storage
10.4”FullColour
Touch Screen Display
Intuitive User Interface
Our steam sterilizers are fitted with a user-friendly and intuitive interface that allows the appropriate cycle to be selected quickly and easily. When the cycle is in progress, important cycle information is displayed. This includes the current stage along with time, temperature and pressure values. The user is informed of any safety concerns via automatic alerts and alarms. Multi-level user access to special menus is password-protected:
- Supervisor access
- Validation
- Machine configuration
- Maintenance
- Cycle log storage
Key Features:
Key Features:
SteamSave
Allowing the autoclave jacket into economy mode when the sterilizer has been left dormant, the controlling pressure of the chamber will automatically be lowered thereby demanding less energy
Compliant with UK and EU regulations
All BMM Weston sterilizers are designed and manufactured in the UK to meet European and International regulatory requirements. Clinical sterilizers comply fully with the Medical Device Directive 93/42/EEC
Additionally all sterilizers comply with the Pressure Equipment Directive 2014/68/EU, Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU
Our Quality Management System operates to ISO 9001:2015 and ISO 13485:2016
Our machines comply with all relevant European standards, along with NHS guidelines CFPP 01-01 Part C
SteamSave
Allowing the autoclave jacket into economy mode when the sterilizer has been left dormant, the controlling pressure of the chamber will automatically be lowered thereby demanding less energy
Compliant with UK and EU regulations
All BMM Weston sterilizers are designed and manufactured in the UK to meet European and International regulatory requirements. Clinical sterilizers comply fully with the Medical Device Directive 93/42/EEC
Additionally all sterilizers comply with the Pressure Equipment Directive 2014/68/EU, Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU
Our Quality Management System operates to ISO 9001:2015 and ISO 13485:2016
Our machines comply with all relevant European standards, along with NHS guidelines CFPP 01-01 Part C
SteamSave
Allowing the autoclave jacket into economy mode when the sterilizer has been left dormant, the controlling pressure of the chamber will automatically be lowered thereby demanding less energy
Compliant with UK and EU regulations
All BMM Weston sterilizers are designed and manufactured in the UK to meet European and International regulatory requirements. Clinical sterilizers comply fully with the Medical Device Directive 93/42/EEC
Additionally all sterilizers comply with the Pressure Equipment Directive 2014/68/EU, Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU
Our Quality Management System operates to ISO 9001:2015 and ISO 13485:2016
Our machines comply with all relevant European standards, along with NHS guidelines CFPP 01-01 Part C
Optional Features
Integral RO
Ensures that the correct quality of water is supplied to the boiler for the production of clean steam.
Integral Air Compressor
Fitted where a plant air supply is not available. The compressor is oil free and quiet in operation.
Variable Cool Drain
Fitted where heat sensitive drain systems are installed to ensure water flowing to drain is at a suitable temperature.
Integral Steam Generator
Integral steam generators are heated either electrically (ESG) or by steam (SSG) and sized to ensure a continuous clean steam supply. Water level is measured by a radar sensor to ensure accurate and reliable performance. Automatic blowdown is fitted as standard to control water quality. Stand alone generators for all configurations and stainless steel steam distribution headers are also available.
Integral RO
Ensures that the correct quality of water is supplied to the boiler for the production of clean steam.
Integral Air Compressor
Fitted where a plant air supply is not available. The compressor is oil free and quiet in operation.
Variable Cool Drain
Fitted where heat sensitive drain systems are installed to ensure water flowing to drain is at a suitable temperature.
Integral Steam Generator
Integral steam generators are heated either electrically (ESG) or by steam (SSG) and sized to ensure a continuous clean steam supply. Water level is measured by a radar sensor to ensure accurate and reliable performance. Automatic blowdown is fitted as standard to control water quality. Stand alone generators for all configurations and stainless steel steam distribution headers are also available.
Integral RO
Ensures that the correct quality of water is supplied to the boiler for the production of clean steam.
Integral Air Compressor
Fitted where a plant air supply is not available. The compressor is oil free and quiet in operation.
Variable Cool Drain
Fitted where heat sensitive drain systems are installed to ensure water flowing to drain is at a suitable temperature.
Integral Steam Generator
Integral steam generators are heated either electrically (ESG) or by steam (SSG) and sized to ensure a continuous clean steam supply. Water level is measured by a radar sensor to ensure accurate and reliable performance. Automatic blowdown is fitted as standard to control water quality. Stand alone generators for all configurations and stainless steel steam distribution headers are also available.
Integral RO
Ensures that the correct quality of water is supplied to the boiler for the production of clean steam.
Integral Air Compressor
Fitted where a plant air supply is not available. The compressor is oil free and quiet in operation.
Variable Cool Drain
Fitted where heat sensitive drain systems are installed to ensure water flowing to drain is at a suitable temperature.
Integral Steam Generator
Integral steam generators are heated either electrically (ESG) or by steam (SSG) and sized to ensure a continuous clean steam supply. Water level is measured by a radar sensor to ensure accurate and reliable performance. Automatic blowdown is fitted as standard to control water quality. Stand alone generators for all configurations and stainless steel steam distribution headers are also available.
axis1
Manual loading trolley
axis2
Electric lift (variable height)
axis3
Electric loading trolley
axis4
Electric lift & Loading trolley
(variable height)
aquasave
Savings when water matters!
BMM Weston offer various levels of water saving to support the demanding economic requirements.
aquasave1 based upon previous S2 configurations
aquasave2 addition of water recovery tank
aquasave3 chilled water loop system required
aquasave1
15% water reduction
aquasave2
50% water reduction
aquasave3
90% water reduction
axis1
Manual loading trolley
axis2
Electric lift (variable height)
axis3
Electric loading trolley
axis4
Electric lift & Loading trolley
(variable height)
aquasave
Savings when water matters!
BMM Weston offer various levels of water saving to support the demanding economic requirements.
aquasave1 based upon previous S2 configurations
aquasave2 addition of water recovery tank
aquasave3 chilled water loop system required
aquasave1
15% water reduction
aquasave2
50% water reduction
aquasave3
90% water reduction
axis1
Manual loading trolley
axis2
Electric lift (variable height)
axis3
Electric loading trolley
axis4
Electric lift & Loading trolley
(variable height)
aquasave
Savings when water matters!
BMM Weston offer various levels of water saving to support the demanding economic requirements.
aquasave1 based upon previous S2 configurations
aquasave2 addition of water recovery tank
aquasave3 chilled water loop system required
aquasave1
15% water reduction
aquasave2
50% water reduction
aquasave3
90% water reduction
Clinical Sterilizers
The sterilizer is intended to process wrapped instruments and utensils, air entrained materials such as linens, gowns, dressings and medical or surgical equipment. The sterilizer, as standard, is fitted with:
• Sterilizing cycles at 134°C and/or 121°C
• Bowie-Dick test
• Leak Rate test
• Air detector function test
• Additional cycles can be configured from a series of discrete stage
Laboratory Sterilizers
Laboratory machines are intended to process glassware, plastic discard, fluids, and textiles as well as the free steaming of culture media. In standard form, the laboratory sterilizer is supplied with six cycles, each configured to perform a separate task, whilst collectively meeting the total need for most laboratory duties:
• Sterilizing cycles from 105°C to 134°C
• Leak rate test
• Cycles can be configured from a series of discrete stages
The Sterilization Cycle
The cycle is designed to achieve rapid and even penetration of steam into the load to produce an effective, fast and repeatable sterilizing process.
In addition to the standard cycles fitted, further cycles can be configured from a series of discrete cycle stages to suit your individual requirements.
Each stage performs a separate function and parameters controlling the function are variable within pre-defined limits. Similarly, the user can ascribe warnings and fault conditions to parameters if they exceed specified limits. The cycle shown below is typical of the stages used in the construction of a wrapped instrument cycle.
Cutting-Edge Visualisation
From detailed building layouts to life-like 3D CAD renderings and walkthroughs, BMM Weston can enable you to clearly visualise your department during the conceptual stages of design in order to optimise workflow and performance.
Designing Your Department
Using our extensive knowledge and decades of experience BMM Weston can support the development of your CSSD from the earliest stages of design all the way through to completion, ensuring the maximum levels of safety, hygiene and efficiency in your department.
Extensive Range of Machines
BMM Weston offers an extensive range of machines to meet your demands and ensure that your needs will be fulfilled in the most cost-effective manner. With horizontal and vertical sliding doors, single-ended and pass-through configurations, a comprehensive range of chamber capacities and the option for integral steam generation, wecan offer a machine well suited to your working environment.
Optimising Performance
BMM Weston can provide expert advice in order to help create a department tailored to your exact requirements -minimising your costs, maximising productivity and preventing bottle necks.Taking into consideration your required workload, availability of space and all other relevant factors we will provide the most suitable machines in an optimal layout to allow your department to run seamlessly
Technical Data
Porous Load Sterilizer Model No. | Laboratory Sterilizer Model No. | STU Capacity (600 x 300 x 300mm) | Volume (litres) | Chamber size (w x h x d mm) | Horizontal/ Vertical Door | Single Ended | Pass through (double door) | Barrier seal available | Integral steam generator available | Overall width & height (mm) | Overall length (mm) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Series | P106 | L106 | 2 | 160 | 350x670x680 | V | 600×1970 | 1100 | ||||
P108 | L108 | 3 | 230 | 350x670x980 | V | 600×1970 | 1400 | |||||
P106D | P106D | 2 | 160 | 350x670x680 | V | 900×1970 | 1000 | |||||
P108D | L108D | 3 | 230 | 350x670x980 | V | 900×1970 | 1300 | |||||
P110 | L110D | 4 | 300 | 350x670x1280 | V | 900×1970 | 1600 | |||||
Series | P210 | L210 | 4 | 370 | 660x700x800 | V | 1200×1905 | 1450 | ||||
P215 | L215 | 6 | 485 | 660x700x1050 | V | 1200×1905 | 1700 | |||||
P221 | L221 | 8 | 600 | 660x700x1300 | V | 900×1970 | 1950 | |||||
P228 | L228 | 10 | 715 | 660x700x1550 | V | 1200×1905 | 2200 | |||||
P232 | L232 | 12 | 830 | 660x700x1800 | V | 1200×1905 | 2450 | |||||
P210D | L210D | 6 | 480 | 660x700x1045 | V | 1200×1905 | 1415 | |||||
P215D | L215D | 8 | 610 | 660x700x1325 | V | 1200×1905 | 1695 | |||||
P221D | L221D | 10 | 740 | 660x700x1605 | V | 1200×1905 | 1975 | |||||
P228D | L228D | 12 | 870 | 660x700x1885 | V | 1200×1905 | 2255 | |||||
Series | P314 | L314 | 6 | 550 | 660x1050x800 | H | 1600×1905 | 1440 | ||||
P321 | L321 | 9 | 725 | 660x1050x1050 | H | 1600×1905 | 1690 | |||||
P328 | L328 | 12 | 900 | 660x1050x1300 | H | 1600×1905 | 1940 | |||||
P332 | L332 | 15 | 1075 | 660x1050x1550 | H | 1600×1905 | 2190 | |||||
P338 | L338 | 15 | 1250 | 660x1050x1800 | H | 1600×1905 | 2440 | |||||
P342 | L342 | 18 | 1420 | 660x1050x2050 | H | 1600×1905 | 2690 | |||||
P321D | L321D | 9 | 725 | 660x1050x1045 | H | 1600×1905 | 1445 | |||||
P328D | L328D | 12 | 920 | 660x1050x1325 | H | 1600×1905 | 1695 | |||||
P332D | L332D | 15 | 1110 | 660x1050x1605 | H | 1600×1905 | 1945 | |||||
P338D | L338D | 18 | 1305 | 660x1050x1885 | H | 1600×1905 | 2195 | |||||
P342D | L342D | 21 | 1500 | 660x1050x2165 | H | 1600×1905 | 2445 | |||||
Series | P440 | L440 | 12 | 1070 | 680x1570x1000 | H | 2100×1930 | 2040 | ||||
P450 | L450 | 16 | 1410 | 680x1570x1320 | H | 2100×1930 | 2360 | |||||
P460 | L460 | 20 | 1750 | 680x1570x1640 | H | 2100×1930 | 2680 | |||||
P470 | L470 | 24 | 2090 | 680x1570x1960 | H | 2100×1930 | 3000 | |||||
P440D | L440D | 12 | 1290 | 680x1570x1210 | H | 2100×1930 | 1750 | |||||
P450D | L450D | 16 | 1630 | 680x1570x1530 | H | 2100×1930 | 2070 | |||||
P460D | L460D | 20 | 1980 | 680x1570x1850 | H | 2100×1930 | 2390 | |||||
P470D | L470D | 24 | 2320 | 680x1570x2170 | H | 2100×1930 | 2710 | |||||
Series | P555 | L555 | 16 | 1660 | 900x1400x1320 | H | 2500×1750 | 1590 | ||||
P570 | L570 | 20 | 2070 | 900x1400x1640 | H | 2500×175 | 1910 | |||||
P585 | L585 | 24 | 2470 | 900x1400x1960 | H | 2500×175 | 2230 | |||||
P5100 | L5100 | 28 | 2870 | 900x1400x2280 | H | 2500×175 | 2550 | |||||
P555D | L555D | 12 | 1520 | 900x1400x1210 | H | 2500×1750 | 1750 | |||||
P570D | L570D | 16 | 1930 | 900x1400x1530 | H | 2500×1750 | 2070 | |||||
P585D | L585D | 20 | 2330 | 900x1400x1850 | H | 2500×1750 | 2390 | |||||
P5100D | L5100D | 24 | 2730 | 900x1400x2170 | H | 2500×1750 | 2710 |